Compliance & Reports
EU F-Gas compliance, fully automated
Zadix Flow runs configured checks relevant to EU Regulation 2024/573 on service events. This guide explains the engine, the checks it runs, and the supporting records and reports.
Architecture
How the Engine Works
Zadix Flow's compliance engine is 100% deterministic code — AI never makes compliance decisions. AI extracts structured data from your photos and voice notes. Then hardcoded rules evaluate every field against EU 2024/573 regulation requirements. The result is a compliance status that is always reproducible and auditable.
Lifecycle
Service Event Lifecycle
Every service event moves through a defined lifecycle from creation to immutable finalization. Each stage triggers a compliance re-evaluation. The record can only move forward — reversing a finalized record is not possible.
Record created but not yet submitted. Fields may be incomplete.
AI has processed attached photos/voice notes and extracted structured data.
Technician has reviewed and confirmed the extracted data is accurate.
Office staff have validated the event against compliance rules.
Owner has finalized the record. Immutable — no further edits possible.
Rules
Configured F-Gas checks
The listed checks are implemented in code and versioned. Their results assist review but do not establish complete legal compliance.
| # | Rule | Severity |
|---|---|---|
| 01 | Refrigerant type required Any refrigerant add/remove event must specify the refrigerant type. | ERROR |
| 02 | Recovery cylinder ID required for disposal Disposal or decommission events must record the recovery cylinder ID. | ERROR |
| 03 | Recovery amount must be recorded When refrigerant is removed, the recovered quantity must be documented. | ERROR |
| 04 | Serial number required for disposal Equipment serial number is mandatory for disposal or decommission actions. | ERROR |
| 05 | Refrigerant source required when adding When refrigerant is added, its source (virgin/recycled/reclaimed) must be declared. | ERROR |
| 06 | Reclamation facility required for reclaimed source If source is reclaimed, the reclamation facility name must be recorded. | ERROR |
| 07 | Recovered gas destination required When refrigerant is removed, its destination (recycled/reclaimed/destroyed) must be declared. | ERROR |
| 08 | Technician F-Gas certificate required F-Gas certificate number of the performing technician must be attached to every record. | ERROR |
| 09 | Service company certificate required The service company F-Gas certificate must be attached to every service record. | ERROR |
| 10 | Follow-up after leak repair Where Article 4(5) applies, the repair must be checked after 24 operating hours and within one month; specified mobile equipment may be checked immediately. | WARNING |
| 11 | Leak check — 5–50 tCO₂e tier Equipment in the 5–50 tonne CO₂e band requires a leak check every 12 months. | WARNING |
| 12 | Leak check — 50–500 tCO₂e tier Equipment in the 50–500 tonne CO₂e band requires a leak check every 6 months. | WARNING |
| 13 | Leak check — >500 tCO₂e tier Equipment above 500 tonne CO₂e requires a leak check every 3 months. | WARNING |
Rules 1–9 are hard ERROR violations. Rules 10–13 are WARNING-level flags. All rules are versioned in source control alongside regulation citations.
Statuses
Compliance Statuses
Every service event carries a compliance status. The engine recalculates the status automatically on each save. Understanding what each status means helps you prioritize which events need attention.
Incomplete data, awaiting more input from the technician or AI.
The configured checks passed. Review the record and applicable legal requirements.
One or more required fields are missing. Action needed before finalization.
Warnings present — no hard violations, but follow-up is recommended.
One or more rule violations detected. Must be resolved before finalization.
Insufficient context to evaluate compliance. Typically missing action type.
Flags
Compliance Flags
When a rule is violated, a compliance flag is raised. Flags carry a severity level, the specific regulation article, and the date of detection. All unresolved flags are surfaced in the dashboard for the office team to action.
Evidence
Evidence Scoring
Each service event receives an evidence score from 0 to 10. The score reflects how well-documented the event is — not whether it is compliant. A high evidence score makes audits significantly smoother and strengthens your position in case of regulatory inspection.
Leak Checks
Leak Check Tiers
EU Regulation 2024/573 mandates periodic leak checks based on the CO₂-equivalent charge of the equipment. Zadix Flow automatically tracks each unit's charge and alerts you when a check is overdue.
| CO₂ Equivalent | Check Frequency |
|---|---|
| 5–50 t CO₂e | Every 12 months |
| 50–500 t CO₂e | Every 6 months |
| >500 t CO₂e | Every 3 months |
Frequencies halve when a certified automatic leak detection system is installed (e.g. 50–500 t tier becomes every 12 months).
Jurisdictions
Country-Specific Rules
Beyond EU-wide rules, many member states have additional national requirements for F-Gas reporting. Zadix Flow is aware of these jurisdictions and surfaces the relevant requirements based on your company's registered country.
ISPRA F-Gas portal reporting required for operators
Registro Nacional de Emisiones reporting mandatory
Fiche d'intervention + BSDD waste tracking required
Naturvårdsverket EPA reporting for operators
HFC tax documentation required for refrigerant purchases
F-Gas Register submission for operators and technicians
Regional certification requirements vary by region
CRO (Central Register of Operators) reporting required
National and UK rules may add or differ from EU requirements. Review them separately.
Records
Immutable Records
Once finalized, a record can never be modified — not even by an admin. This is enforced at the database level with a PostgreSQL trigger that blocks any UPDATE or DELETE on finalized records. A SHA-256 hash of the record content is stored at finalization time.
PostgreSQL trigger
A BEFORE UPDATE OR DELETE trigger on the service_events table raises an exception if status = finalized.
SHA-256 hash
A hash of all record fields is stored at finalization. Any tampering at the database level is detectable by re-hashing the record.
Records
PDF Certificates
Every finalized service event can be exported as a signed PDF certificate. The certificate includes all field data, the compliance status, technician and company certificates, and the SHA-256 record hash — suitable for regulatory submission or customer delivery.
Records
Annual Reports
Zadix Flow generates annual F-Gas compliance reports suitable for submission to national regulators. Reports can be scoped by date range, technician, equipment, or action type, and exported as PDF or CSV.
Annual report includes:
- Total refrigerant added and recovered per equipment unit, aggregated by refrigerant type and GWP
- All compliance flags raised during the period, with resolution status and responsible party
- Technician certification status at time of each service event
- Leak check schedule adherence — all overdue checks flagged with days overdue
- Equipment with non-compliant or incomplete records, listed with event references
Records
Equipment Logbook
EU 2024/573 requires operators to maintain a logbook for each refrigerant-containing system above 5 tCO₂e. Zadix Flow maintains this automatically — every service event is appended to the relevant equipment's logbook in chronological order. The logbook is exportable as a PDF at any time, pre-formatted to match the EU standard logbook template. Field snapshots are taken at event creation so the logbook reflects the equipment's state at the time of service, even if asset data changes later.
Records
Refrigerant Balance
The refrigerant balance view gives you a running total of every refrigerant purchased, added to equipment, recovered, and destroyed — by refrigerant type and period. This is the data you need for annual reporting to national regulators and for tracking your company's total F-Gas use against quota limits. Discrepancies between purchased and recorded quantities are automatically flagged as potential unrecorded releases.
Monitoring
Risk Overview
The risk overview on the main Dashboard aggregates all open compliance issues into an estimated fine exposure figure, calculated against the EU 2024/573 penalty schedule. Use it to prioritize your team's attention and demonstrate to your clients that compliance is proactively managed.
Monitoring
Escalation Timeline
Unresolved events follow an automatic escalation path. The system monitors each event from the moment the technician confirms, and escalates through reminders, dashboard flags, and risk promotions until the record is finalized.
Technician reviews AI extraction and confirms the service event data is accurate.
Office staff checks the event against compliance rules and validates completeness.
Account owner reviews and finalizes the record. It becomes immutable at this point.
If still unfinalized after 7 days, the event is flagged as stale in the dashboard.
An automated WhatsApp reminder is sent to the responsible team member.
Event is promoted to the main Dashboard as an open compliance exposure item.